← All pages
Mesa/Boogie Mark IIC+ reissue · Power amp · 6L6GC

Mark IIC+ Power Tube Readings

Flip the Simul-Class / Class A switch to compare the two modes.

Simul-Class / Class A

Rear panel · the amp's only power-amp switch

Plate supply (B+)
Tubes conducting
Both modes at a glance
TubeOperationP3 plateP4 screenP5 gridP8 cathodeEff. biasPlate currentIdle plate dissipation% of 30 W max

Tubes are grouped by pair: A and D are the outer (end) pair, B and C the inner (middle) pair. Readings at idle (no signal) with mains at about 121 VAC, voltages to chassis ground, plate current from a plate-current probe; values rounded to whole numbers. Effective bias = P5 − P8. Idle plate dissipation = (P3 − P8) × plate current: the heat each tube's plate dissipates at rest, against the 6L6GC's 30 W maximum. It is not the amp's output power.